For a large water, effluent or biogas tank in India, the usual choices are reinforced cement concrete (RCC), steel with a painted or epoxy coating, stainless steel and glass fused steel (GFS). Each can be the right answer. This guide sets out what to weigh up.
RCC tanks
RCC is familiar to every contractor and suits underground sumps and tanks that are part of a building. Its drawbacks for process tanks are the time it takes to cast and cure, the risk of cracks and leaking joints as it ages, and attack on the concrete by acidic effluent and the hydrogen sulphide in biogas, which often means adding a protective lining. An RCC tank cannot be moved or easily enlarged.
Painted or epoxy-coated steel tanks
Steel tanks with an epoxy or painted coating are quick to build and cost less than stainless steel. The coating is the weak point: it can be scratched or worn, and coatings applied on site depend on site conditions. Plan for inspection and recoating over the tank's life. Epoxy coatings can be repaired on site, which is an advantage. Factory-applied fusion bonded epoxy (FBE) tanks avoid the site-painting problem: the powder coating is cured in an oven before the panels are bolted together.
Stainless steel tanks
Bolted SS304 and SS316 tanks need no coating at all and suit high-purity water, food and dairy liquids and some biogas digesters. Stainless steel is usually the most expensive option, and the grade has to be matched to the chlorides and chemicals in the liquid.
Glass fused steel tanks
GFS tanks put a factory-fired glass coating on both faces of the steel, 230–480 microns thick, with 5,000 psi adhesion and a hardness of 6.0 Mohs. The glass resists pH 3–11 as standard (pH 1–14 for special grades), does not need repainting and lasts 30 years or more. Because the sheets are bolted, a tank goes up in weeks rather than months, and it can later be extended, dismantled or moved. The trade-off is that the glass is fired in a factory, so it is handled with care on site, and joints are sealed with sealant during erection.
Quick comparison
| RCC | Epoxy-coated steel | Stainless steel | Glass fused steel | |
|---|---|---|---|---|
| Build time | Slow (casting, curing) | Fast | Fast (bolted) | Fast (bolted) |
| Corrosion protection | Concrete; lining for effluent | Epoxy coating | The steel itself | Fired glass, both faces |
| Upkeep | Crack and joint repair | Inspect and recoat | Low | Low, no repainting |
| Expand or relocate | No | Yes if bolted | Yes if bolted | Yes |
Which to choose
- Drinking water and fire water above ground: GFS with an aluminium dome roof, or epoxy-coated steel on a tight budget.
- ETP, STP and leachate: GFS in the 2C2F or 3C3F grade, chosen by the effluent's pH.
- Biogas and CBG digesters: GFS, or stainless steel where specified.
- High-purity or food-grade liquids: stainless steel.
- Underground sumps: RCC.
Compare quotations on the same volume, roof and accessories, and ask about expected life and maintenance, not only the first cost.
Pragmatic Sales & Services, Pune, is an authorised Center Enamel dealer and supplies tanks across India; installation is done by Center Enamel or by installers it has trained in India. Tell us what you need to store, how much and where, and we will help you choose the tank, enamel grade and roof and get you a quotation. Call +91-9822081118 or send us your requirement.